background image

IPv4 Software Access Control List (ACL) Commands

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

35.41

maximum-access-list

Sets the maximum number of filters that can be added to any access-list. These are access-
lists within the ranges <1-199>, <1300-1999> and <2000-2699> and named standard and
extended access-lists.

The no variant of this command removes the limit on the number of filters that can be
added to a software access-list

Syntax

maximum-access-list <1-4294967294>

no maximum-access-list

Mode

Global Configuration

Example

To set the maximum number of software filters to 200:

Parameter

Description

<1-4294967294>

Filter range.

awplus#

configure terminal

awplus(config)#

maximum-access-list 200