show power-inline counters
This command displays Power over Ethernet (PoE) event counters for ports on the Power
Sourcing Equipment (PSE). The PoE event counters displayed can also be accessed by
objects in the PoE MIB (RFC 3621). See
for information about
which PoE MIB objects are supported.
For information on output options, see
“Controlling “show” Command Output” on
Syntax
show power-inline counters [<port-list>]
Mode
User Exec and Privileged Exec
Usage
To display all PoE event counters for all PoE ports on the PSE, do not enter the optional
interface parameter.
Examples
To display all PoE event counters for all PoE ports on the PSE, use the command:
To display the PoE event counters for the port range 1.0.1 to 1.0.3, use the command:
Output
Figure 23-3: Example output from the show power-inline counters command
Parameter
Description
<port-list>
Enter the PoE port(s) to display all PoE event counters for them.
awplus#
show power-inline counters
awplus#
show power-inline counters interface port1.0.1-1.0.3
awplus#show power-inline counters interface port1.0.4-port1.0.12
PoE Counters:
Interface MPSAbsent Overload Short Invalid Denied
port1.0.4 0 0 0 0 0
port1.0.5 0 0 0 0 0
port1.0.6 0 0 0 0 0
port1.0.7 0 0 0 0 0
port1.0.8 0 0 0 0 0
port1.0.9 0 0 0 0 0
port1.0.10 0 0 0 0 0
port1.0.11 0 0 0 0 0
port1.0.12 0 0 0 0 0