time (trigger)

This command specifies the time of day when the trigger is permitted to activate. The
after parameter specifies the start of a time period that extends to midnight during which
trigger may activate. By default the value of this parameter is 00:00:00 (am); that is, the
trigger may activate at any time. The before parameter specifies the end of a time period
beginning at midnight during which the trigger may activate. By default the value of this
parameter is 23:59:59; that is, the trigger may activate at any time. If the value specified for
before is later than the value specified for after, a time period from "after" to "before" is
defined, during which the trigger may activate. This command is not applicable to time
triggers (type time).

The following figure illustrates how the before and after parameters operate.

Syntax

time {[after <hh:mm:ss>] [before <hh:mm:ss>]}

Mode

Trigger Configuration

Usage

For example trigger configurations that use the time (trigger) command, see

“Restrict

Internet Access” on page 76.2

and

“Turn Off Power to Port LEDs” on page 76.7

.

00:00

06:00

12:00

18:00

00:00

00:00

06:00

12:00

18:00

00:00

00:00

06:00

12:00

18:00

00:00

00:00

06:00

12:00

18:00

00:00

BEFORE=08:00

AFTER=18:00

AFTER=18:00 BEFORE=08:00

AFTER=08:00 BEFORE=18:00

Period when trigger may activate.

Key:

Period when trigger may not activate.

TRG_02

Parameter

Description

after

<hh:mm:ss>

The earliest time of day when the trigger may be activated.

before

<hh:mm:ss>

The latest time of day when the trigger may be activated.