System Configuration and Monitoring Commands
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
8.55
■
Power Monitoring: Displays the received power measurement type, which can be
either OMA (Optical Module Amplitude) or Avg (Average Power) measured in μW.
Example
To display detailed information about the pluggable transceivers installed in a particular
port on the switch, use a command like:
To display detailed information about all the pluggable transceivers installed on the
switch, use the command:
Output
Figure 8-25: Example output from the show system pluggable detail command on a
switch
Note
For parameters that are not supported or not specified, a hyphen is displayed
instead.
awplus#
show system pluggable port1.0.24 detail
awplus#
show system pluggable detail
awplus#show system pluggable port1.0.24 detail
System Pluggable Information Detail
Port1.0.24
==========
Vendor Name: AGILENT
Device Name: HFCT-5710L
Device Type: 1000BASE-LX
Serial Number: 0402142241184360
Manufacturing Datecode: 040214
SFP Laser Wavelength: -
Link Length Supported
Single Mode Fiber : 10Km
OM1 (62.5um) Fiber: 550m
OM2 (50um) Fiber : 550m
Diagnostic Calibration: Internal
Power Monitoring: Avg
FEC BER support: -