Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 1313

Local RADIUS Server Introduction and Configuration
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
50.11
15
Login-Service
Integer. Valid values are:
■
LAT (4)
■
PortMaster (3)
■
Rlogin (1)
■
TCP-Clear (2)
■
TCP-Clear-Quiet (8)
■
Telnet (0)
■
X25-PAD (5)
■
X25-T3POS (6)
16
Login-TCP-Port
Integer. Valid values are:
■
Rlogin (513)
■
Rsh (514)
■
Telnet (23)
18
Reply-Message
string
19
Callback-Number
string
20
Callback-Id
string
22
Framed-Route
string
23
Framed-IPX-Network
IP address
24
State
octets (Hexadecimal string followed by 0x)
25
Class
octets (Hexadecimal string followed by 0x)
26
Vendor-Specific
Use the Vendor-specific Attribute Name. For valid
values, see
27
Session-Timeout
Integer
28
Idle-Timeout
Integer
29
Termination-Action
Integer. Valid values are:
■
Default (0)
■
RADIUS-Request (1)
30
Called-Station-Id
string
31
Calling-Station-Id
string
32
NAS-Identifier
string
33
Proxy-State
octets (Hexadecimal string followed by 0x)
34
Login-LAT-Service
string
35
Login-LAT-Node
string
36
Login-LAT-Group
octets (Hexadecimal string followed by 0x)
37
Framed-AppleTalk-Link
Integer
38
Framed-AppleTalk-
Network
Integer
Table 50-1: Standard RADIUS Attributes(cont.)
Attribute ID and Name
Value Type/Pre-defined Values