beautypg.com

Diagnostic menu – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual

Page 67

background image

Start-up Sequence

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

3.3

Diagnostic Menu

Enter Ctrl+D during start-up to access the bootloader diagnostic menu, and provide
options for performing various hardware tests. This can be useful as a tool for confirming a
suspected hardware problem at the direction of network engineering personnel. When
you enter Ctrl+D, the stage 1 diagnostics menu is displayed:

The options in the stage 1 diagnostics menu allow you to initiate the following tests:

RAM
The Bootloader fully tests any/all SDRAM installed in the system.

NVS
The Bootloader fully tests any/all non-volatile (battery backed) SRAM installed in the
system.

checksum
The Bootloader checksum ROM memory for error detection.

For example, enter “2” to select a Quick RAM test:

Enter “7” to display the stage 2 diagnostics menu:

Bootup Stage 1 Diagnostics Menu:
0. Restart
1. Full RAM test
2. Quick RAM test
3. Battery backed RAM (NVS) test
4. Bootloader ROM checksum test
----------------------------------
7. Bootup stage 2 diagnostics menu
----------------------------------
8. Quit to U-Boot shell
9. Quit and continue booting
Enter selection ==>

Quick RAM test - press Q to quit, S to skip when failing
Writing pattern ................................
Checking pattern ................................
Writing complemented pattern ....................
Checking complemented pattern ...................
Pass 1 total errors 0

Entering stage 2...
Bootup Stage 2 Diagnostics Menu:
0. Restart
2. Test FLASH (Filesystem only)
4. Erase FLASH (Filesystem only)
5. Card slot test
----------------------------------
8. Quit to U-Boot shell
9. Quit and continue booting