At-envmonv2-mib – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 1833
SNMP MIBs
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
69.21
AT-ENVMONv2-MIB
The AT Environment Monitoring v2 MIB (atEnvMonv2-MIB) has the object path
207.8.4.4.3.12. It contains objects for managing and reporting data relating to fans,
voltage rails, temperature sensors and power supply units installed in the device (
). Objects in this group have the object identifier EnvMonv2 ({ sysinfo 12 }).
Table 69-8: Objects defined in AT-ENVMONV2-MIB
Object / Object Identifier
Description
atEnvMonv2Notifications
{ atEnvMonv2 0 }
OID (207.8.4.4.3.12.0)
A collection of traps (notification) objects for monitoring
fans, voltage rails, temperature sensors, and power supply
bays.
atEnvMonv2FanAlarmSetNotify
{ atEnvMonv2Notifications 1 }
OID (207.8.4.4.3.12.0.1)
A notification that is generated when the monitored speed
of a fan drops below its lower threshold. It returns the
value of:
1. atEnvMonv2FanStackMemberId
2. atEnvMonv2FanBoardIndex
3. atEnvMonv2FanIndex
4. atEnvMonv2FanDescription
5. atEnvMonv2FanLowerThreshold
6. atEnvMonv2FanCurrentSpeed
atEnvMonv2FanAlarmClearedNotify
{ atEnvMonv2Notifications 2 }
Notification generated when the monitored speed of a fan
returns to an acceptable value, the fan having previously
been in an alarm condition. It returns the value of:
1. atEnvMonv2FanStackMemberId
2. atEnvMonv2FanBoardIndex
3. atEnvMonv2FanIndex
4. atEnvMonv2FanDescription
5. atEnvMonv2FanLowerThreshold
6. atEnvMonv2FanCurrentSpeed
atEnvMonv2VoltAlarmSetNotify
{ atEnvMonv2Notifications 3 }
Notification generated when the voltage of a monitored
voltage rail, goes out of tolerance by either dropping
below its lower threshold, or exceeding its upper
threshold. It returns the value of:
1. atEnvMonv2VoltageStackMemberId
2. atEnvMonv2VoltageBoardIndex
3. atEnvMonv2VoltageIndex
4. atEnvMonv2VoltageDescription
5. atEnvMonv2VoltageUpperThreshold
6. atEnvMonv2VoltageLowerThreshold
7. atEnvMonv2VoltageCurrent (i.e. the voltage currently
being measured).