show system pluggable detail

This command displays detailed pluggable transceiver information showing the
pluggable type, the pluggable serial number, and the pluggable port on the switch.
Different types of pluggable transceivers are supported in different models of switch. See
your Allied Telesis dealer for more information about the models of pluggables that your
switch supports.

For information on output options, see

“Controlling “show” Command Output” on

page 1.37

.

Syntax

show system pluggable [<port-list>] detail

Mode

User Exec and Privileged Exec

Usage

For a stacked configuration, if this command is entered on the stack master, it will display
detailed information about the pluggable transceivers for all the stack members. A stack
member heading will be displayed to distinguish the different pluggable transceiver
information for every stack member.

In addition to the information about pluggable transceivers displayed using the

show

system pluggable

command (port, manufacturer, serial number, manufacturing

datecode, and type information), the show system pluggable detail command displays
the following information:

SFP Laser Wavelength: Specifies the laser wavelength of the installed pluggable
transceiver

Single mode Fiber: Specifies the link length supported by the pluggable transceiver
using single mode fiber

OM1 (62.5μm) Fiber: Specifies the link length (in μm - micron) supported by the
pluggable transceiver using 62.5 micron multi-mode fiber.

OM2 (50 μm) Fiber: Specifies the link length (in μm - micron) supported by the
pluggable transceiver using 50 micron multi-mode fiber.

Diagnostic Calibration: Specifies whether the pluggable transceiver supports DDM
or DOM Internal or External Calibration.

«

Internal is displayed if the pluggable transceiver supports DDM or DOM Internal
Calibration.

«

External is displayed if the pluggable transceiver supports DDM or DOM External
Calibration.

«

- is displayed if SFP or SFP+ DDM Internal Calibration or External Calibration is not
supported.

Parameter

Description

The ports to display information about. The port list can be:

a switch port (e.g. port1.0.12)

a continuous range of ports separated by a hyphen,
e.g. port1.0.1-1.0.24

a comma-separated list of ports and port ranges,
e.g. port1.0.1,port1.0.4-1.2.24.