beautypg.com

Power-inline allow-legacy, No power-inline allow-legacy – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual

Page 603

background image

Power over Ethernet Commands

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

23.5

To disable all PoE debugging and stop the display of any PoE debugging messages on the
console, use the following command:

Validation

Commands

show debugging power-inline

Related Commands

terminal monitor

power-inline allow-legacy

This command enables detection of pre-IEEE 802.3af Power Ethernet standard legacy
Powered Devices (PDs).

The no variant of this command disables detection of pre-IEEE 802.3af Power Ethernet
standard legacy Powered Devices (PDs).

Syntax

power-inline allow-legacy

no power-inline allow-legacy

Default

Detection of legacy PDs is enabled on all ports on the Power Sourcing Equipment (PSE).

Mode

Global Configuration

Examples

To disable detection of legacy PDs, use the following commands:

To enable detection of legacy PDs, use the following commands:

Validation

Commands

show power-inline
show running-config power-inline

awplus#

no debug power-inline all

awplus#

configure terminal

awplus(config)#

no power-inline allow-legacy

awplus#

configure terminal

awplus(config)#

power-inline allow-legacy