SNMP MIBs
Software Reference for x310 Series Switches
69.24
AlliedWare Plus
TM
Operating System - Version 5.4.4C
C613-50046-01 REV A
atEnvMonv2FanStatus
{ atEnvMonv2FanEntry 7 }
Whether this fan is currently in an alarm condition. The
values can be:
1. Failed. Means that the current speed is too low.
2. Good. Means that the current speed is acceptable.
atEnvMonv2VoltageTable
{ atEnvMonv2 2 }
Table of information about voltage rails in the device that
are monitored by environment monitoring hardware,
indexed by:
1. atEnvMonv2VoltageStackMemberId
■
atEnvMonv2VoltageBoardIndex
■
atEnvMonv2VoltageIndex
atEnvMonv2VoltageEntry
{ atEnvMonv2VoltageTable 1 }
Description, current value, upper & lower threshold
settings and current status of a single voltage rail.
atEnvMonv2VoltageStackMemberId
{ atEnvMonv2VoltageEntry 1 }
Index of the stack member hosting this voltage sensor.
atEnvMonv2VoltageBoardIndex
{ atEnvMonv2VoltageEntry 2 }
Index of the board hosting this voltage sensor in the board
table.
atEnvMonv2VoltageIndex
{ atEnvMonv2VoltageEntry 3 }
Numeric identifier of this voltage rail on its host board.
atEnvMonv2VoltageDescription
{ atEnvMonv2VoltageEntry 4 }
Description of this voltage rail.
atEnvMonv2VoltageCurrent
{ atEnvMonv2VoltageEntry 5 }
Current reading of this voltage rail in millivolts.
atEnvMonv2VoltageUpperThreshold
{ atEnvMonv2VoltageEntry 6 }
Maximum acceptable reading of this voltage rail in
millivolts.
atEnvMonv2VoltageLowerThreshold
{ atEnvMonv2VoltageEntry 7 }
Minimum acceptable reading of this voltage rail in
millivolts.
atEnvMonv2VoltageStatus
{ atEnvMonv2VoltageEntry 8 }
Whether this voltage rail is currently in an alarm condition.
Possible values are:
1. outOfRange (1) - means that the current reading is
outside the threshold range.
2. inRange (2) - means that the current reading is
acceptable.
atEnvMonv2TemperatureTable
{ atEnvMonv2 3 }
Table of information about temperature sensors in the
device that are monitored by environment monitoring
hardware, indexed by:
1. atEnvMonv2TemperatureStackMemberId
2. atEnvMonv2TemperatureBoardIndex
3. atEnvMonv2TemperatureIndex
4. atEnvMonv2TemperatureDescription
5. atEnvMonv2TemperatureCurrent
6. atEnvMonv2TemperatureUpperThreshold
7. atEnvMonv2TemperatureStatus
atEnvMonv2TemperatureEntry
{ atEnvMonv2TemperatureTable 1 }
Description, current value, upper threshold setting and
current status of a single temperature sensor.
atEnvMonv2TemperatureStackMemberId
{ atEnvMonv2TemperatureEntry 1 }
Index of the stack member hosting this temperature
sensor.
atEnvMonv2TemperatureBoardIndex
{ atEnvMonv2TemperatureEntry 2 }
Index of the board hosting this temperature sensor in the
board table.
Table 69-8: Objects defined in AT-ENVMONV2-MIB(cont.)
Object / Object Identifier
Description