VCStack Introduction

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

82.17

To apply a trigger upon transition from active master state to disabled master state, use
the command:

To apply a trigger upon transition from disabled master state to active master state, use
the command:

awplus#

type stack disabled-master

awplus#

type stack master-fail

Note

A disabled master trigger allows you to specify a script to reconfigure the
disabled master on the fly, should a catastrophic failure separate the stack. This
is useful to configure an alternate IP address so you can still log in to the
disabled master via an SSH or a Telnet connection. The trigger script should use
the no shutdown command to re-enable any switchports needed for an SSH or
a Telnet management connection.