ipv6 nd ra-lifetime
Use this command to specify the time period that this router can usefully act as a default
gateway for the network. Each router advertisement resets this time period.
Use no parameter with this command to reset the value to default.
Syntax
ipv6 nd ra-lifetime <seconds>
no ipv6 nd ra-lifetime
Default
1800 seconds
Mode
Interface Configuration for a VLAN interface.
Usage
This command specifies the lifetime of the current router to be announced in IPv6 Router
Advertisements.
Advertisement flags will not be transmitted unless you have applied the
command. This instruction is included in the example shown below.
Examples
To set the advertisement lifetime of 8000 seconds on the VLAN interface vlan4, use the
following commands:
Related Commands
ipv6 nd suppress-ra
ipv6 nd prefix
Parameter
Description
<seconds>
Time period in seconds. Valid values are from 0 to 9000.
Note that you should set this time period to a value greater than the
value you have set using the
command.
awplus#
configure terminal
awplus(config)#
interface vlan4
awplus(config-if)#
ipv6 nd ra-lifetime 8000
awplus(config-if)#
no ipv6 nd suppress-ra