SNMP Commands
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
68.17
Usage
This command cannot be used to enable link status notifications globally. To enable link
status notifications for particular interfaces, use the
command.
To specify where notifications are sent, use the
command.
Note that more than one trap can be configured with one command entry, and also note
this command applied to notifications send by SNMP version 3.
Examples
To enable the device to send PoE related traps, use the following commands:
To disable PoE traps being sent out by the switch, use the following commands:
To enable the device to send MAC address Thrash Limiting traps, use the following
commands:
To disable the device from sending MAC address Thrash Limiting traps, use the following
commands:
To enable the device to send OSPF and VRRP-related traps, use the following commands:
To disable OSPF traps being sent out by the switch, use the following commands:
Related Commands
show snmp-server
show ip dhcp snooping
snmp trap link-status
snmp-server host
awplus#
configure terminal
awplus(config)#
snmp-server enable trap power-inline
awplus#
configure terminal
awplus(config)#
no
snmp-server enable power-inline
awplus#
configure terminal
awplus(config)#
snmp-server enable trap thrash-limit
awplus#
configure terminal
awplus(config)#
no snmp-server enable trap thrash-limit
awplus#
configure terminal
awplus(config)#
snmp-server enable trap ospf vrrp
awplus#
configure terminal
awplus(config)#
no
snmp-server enable trap ospf