Stacking Commands
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
83.15
Related Commands
show counter stack
show stack resiliencylink
stack disabled-master-monitoring
stack resiliencylink
stack software-auto-synchronize
Priority
Stack member master election priority (between 1 and 255)
Note that the lowest number has the highest priority.
Product Type
Stack member product type. For example, x310-26FT.
Provisioned
Indicates that the stack position is provisionally configured, i.e.
ready to accept a particular switch type into the stack.
Resiliency link
status
The current status of the resiliency link. The status can be one
of:
■
Not configured, (Master or Member).
■
Configured (Master only).
■
Successful:
Successfully receiving healthchecks from the Active Master.
■
Failed (Member only):
Not receiving any healthchecks from the Active Master.
■
Stopped:
The resiliency link is configured, but is inactive. This may
occur in a Disabled Master stack, for example if the Disabled
Master Monitoring feature is not used.
Role
Stack member’s role in the stack, this can be one of:
■
Active Master.
■
Disabled Master (The temporary master when there is a
communication break within the stack, but communication
still exists across the resiliency link. In this state all switch
ports within the stack are disabled by default, but a different
configuration can be run by a “
trigger command).
■
Backup Member (a device other than the stack master).
■
Discovering - joining the stack.
Status
Indicates how readily a stack member can take over as master if
the current stack master were to fail.
■
Init - the stack member is completing the startup
initialization.
■
Syncing - the stack member is synchronizing state
information with the stack master following startup.
■
Ready - the stack member is fully synchronized with the
current master and is ready to take over immediately.
Table 83-4: Parameters in the output from the show stack detail command(cont.)
Parameter