Clock summer-time recurring, Clock summer-time – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 208
System Configuration and Monitoring Commands
Software Reference for x310 Series Switches
8.8
AlliedWare Plus
TM
Operating System - Version 5.4.4C
C613-50046-01 REV A
clock summer-time recurring
This command defines the start and end of summertime for every year, and specifies
summertime’s offset value to Standard Time.
The no variant of this command removes the device’s summertime setting. This clears
both specific summertime dates (set with the
clock summer-time date command on
) and recurring dates.
By default, the device has no summertime definitions set.
Syntax
clock summer-time
no clock summer-time
Mode
Global Configuration
Parameter
Description
A description of the summertime zone, up to 6 characters long.
recurring
Specifies that this summertime setting applies every year from
now on.
Week of the month when summertime starts, in the range 1-5. The
value 5 indicates the last week that has the specified day in it for
the specified month. For example, to start summertime on the last
Sunday of the month, enter 5 for
and sun for
.
Day of the week when summertime starts. Valid values are mon,
tue, wed, thu, fri, sat or sun.
First three letters of the name of the month that summertime
starts.
Time of the day that summertime starts, in the 24-hour time
format HH:MM.
Week of the month when summertime ends, in the range 1-5. The
value 5 indicates the last week that has the specified day in it for
the specified month. For example, to end summertime on the last
Sunday of the month, enter 5 for
and sun for
day>
.
Day of the week when summertime ends. Valid values are mon,
tue, wed, thu, fri, sat or sun.
First three letters of the name of the month that summertime ends.
Time of the day that summertime ends, in the 24-hour time format
HH:MM.
<1-180>
The offset in minutes.