Switchport resiliencylink, Undebug stack, Switchport resiliencylink undebug stack – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 2170
![background image](/manuals/427254/2170/background.png)
Stacking Commands
Software Reference for x310 Series Switches
83.30
AlliedWare Plus
TM
Operating System - Version 5.4.4C
C613-50046-01 REV A
switchport resiliencylink
This command configures the switch port to be a member of the stack resiliency link
VLAN. Note that this switchport will only be used for stack resiliency-link traffic and will
not perform any other function, or carry any other traffic.
The no variant of this command removes the switchport from the resiliency link VLAN.
Syntax
switchport resiliencylink
no switchport resiliencylink
Mode
Global Configuration to create then Interface Configuration to assign the resiliency link.
Examples
To set the resiliency link to be VLAN 4093:
First, use the
stack resiliencylink
command to create the resiliency vlan4093
Next, use the
switchport resiliencylink
command to assign the resiliencylink vlan to the
port, in this case port1.0.1.
Related Commands
stack resiliencylink
show stack resiliencylink
undebug stack
This command applies the functionality of the
no
debug stack command on page 83.3
.
awplus#
configure terminal
awplus(config)#
stack resiliencylink vlan4093
awplus#
configure terminal
awplus(config)#
interface port1.0.1
awplus(config-if)#
switchport resiliencylink