Power-inline description – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 604
Power over Ethernet Commands
Software Reference for x310 Series Switches
23.6
AlliedWare Plus
TM
Operating System - Version 5.4.4C
C613-50046-01 REV A
power-inline description
This command adds a description for a Powered Device (PD) connected to a PoE port.
The no variant of this command clears a previously entered description for a connected
PD, resetting the PD description to the default (null).
Syntax
power-inline description <pd-description>
no power-inline description
Default
No description for a connected PD is set by default.
Mode
Interface Configuration
Usage
Select a PoE port, a list of PoE ports, or a range of PoE ports with the preceding
command. If you specify a range or list of ports they must all be PoE
capable ports.
Examples
To add the description Desk Phone for a connected PD on port1.0.2, use the
following commands:
To clear the description as added above for the connected PD on port1.0.2, use the
following commands:
Validation
Commands
show power-inline interface
show running-config power-inline
Parameter Description
<pd-description>
Description of the PD connected to the PoE capable port
(with a maximum 256 character string limit per PD
description).
awplus#
configure terminal
awplus(config)#
interface port1.0.2
awplus(config-if)#
power-inline description Desk Phone
awplus#
configure terminal
awplus(config)#
interface port1.0.2
awplus(config-if)#
no power-inline description