Power over Ethernet Commands

Software Reference for x310 Series Switches

23.6

AlliedWare Plus

TM

Operating System - Version 5.4.4C

C613-50046-01 REV A

power-inline description

This command adds a description for a Powered Device (PD) connected to a PoE port.

The no variant of this command clears a previously entered description for a connected
PD, resetting the PD description to the default (null).

Syntax

power-inline description <pd-description>

no power-inline description

Default

No description for a connected PD is set by default.

Mode

Interface Configuration

Usage

Select a PoE port, a list of PoE ports, or a range of PoE ports with the preceding

interface

(to configure)

command. If you specify a range or list of ports they must all be PoE

capable ports.

Examples

To add the description Desk Phone for a connected PD on port1.0.2, use the
following commands:

To clear the description as added above for the connected PD on port1.0.2, use the
following commands:

Validation

Commands

show power-inline interface
show running-config power-inline

Parameter Description

<pd-description>

Description of the PD connected to the PoE capable port
(with a maximum 256 character string limit per PD
description).

awplus#

configure terminal

awplus(config)#

interface port1.0.2

awplus(config-if)#

power-inline description Desk Phone

awplus#

configure terminal

awplus(config)#

interface port1.0.2

awplus(config-if)#

no power-inline description