Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 607
Power over Ethernet Commands
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
23.9
See the actual value used, as shown after command entry, in the sample console output
below:
Refer to
Chapter 70, LLDP, LLDP-MED and Voice VLAN Introduction and
and
for information about power
monitoring at the PD.
Note the difference in power supplied from the PSE to the power available at the PD due
to line loss.
The
shows the difference between the power supplied
from the PSE and the power available at the PD.
Examples
To set the maximum power supplied to ports in the range 1.0.2 to 1.0.4 to
6450mW per port, use the following commands:
To set the maximum power supplied to port1.0.2, to 6450 mW, use the following
commands:
To clear the user-configured maximum power supplied to port1.0.2, and revert to
using the default maximum power of 30000 mW, use the following commands:
Validation
Commands
show power-inline interface
show running-config power-inline
awplus#configure terminal
awplus(config)#interface port1.0.1
awplus(config-if)#power-line max 5300
% The maximum power has been rounded to 5450mW in hardware.
awplus#
configure terminal
awplus(config)#
interface port1.0.2-port1.0.4
awplus(config-if)#
power-inline max 6450
awplus#
configure terminal
awplus(config)#
interface port1.0.2
awplus(config-if)#
power-inline max 6450
awplus#
configure terminal
awplus(config)#
interface port1.0.2
awplus(config-if)#
no power-inline max