Trigger Commands

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

77.17

Examples

To allow trigger 63 to activate between midnight and 10:30am, use the commands:

To allow trigger 64 to activate between 3:45pm and midnight, use the commands:

To allow trigger 65 to activate between 10:30am and 8:15pm, use the commands:

Related Commands

show trigger
trigger

awplus#

configure terminal

awplus(config)#

trigger 63

awplus(config-trigger)#

time before 10:30:00

awplus#

configure terminal

awplus(config)#

trigger 64

awplus(config-trigger)#

time after 15:45:00

awplus#

configure terminal

awplus(config)#

trigger 65

awplus(config-trigger)#

time after 10:30:00 before 20:15:00