spanning-tree errdisable-timeout enable

Use this command to enable the errdisable-timeout facility, which sets a timeout for ports
that are disabled due to the BPDU guard feature.

Use this command for RSTP or MSTP.

Use the no variant of this command to disable the errdisable-timeout facility.

Syntax

spanning-tree errdisable-timeout enable

no spanning-tree errdisable-timeout enable

Default

By default, the errdisable-timeout is disabled.

Mode

Global Configuration

Usage

The BPDU guard feature shuts down the port on receiving a BPDU on a BPDU-guard
enabled port. This command associates a timer with the feature such that the port is re-
enabled without manual intervention after a set interval. This interval can be configured
by the user using the

spanning-tree errdisable-timeout interval

command.

Example

Related Commands

show spanning-tree
spanning-tree errdisable-timeout interval
spanning-tree portfast bpdu-guard

awplus#

configure terminal

awplus(config)#

spanning-tree errdisable-timeout enable