Trigger Commands
Software Reference for x310 Series Switches
77.24
AlliedWare Plus
TM
Operating System - Version 5.4.4C
C613-50046-01 REV A
type periodic
This command configures a trigger to be activated at regular intervals. The time period
between activations is specified in minutes.
Syntax
type periodic <1-1440>
Mode
Trigger Configuration
Usage
A combined limit of 10 triggers of the type periodic and time can be configured. If you
attempt to add more than 10 triggers the following error message is displayed:
For an example trigger configuration that uses the type periodic command, see
Daily Statistics” on page 76.6
Example
To configure trigger 44 to activate periodically at 10 minute intervals use the following
commands:
Related Commands
Parameter
Description
<1-1440>
The number of minutes between activations.
% Cannot configure more than 10 triggers with the type time or
periodic
awplus#
configure terminal
awplus(config)#
trigger 44
awplus(config-trigger)#
type periodic 10