timeout (ping polling)
This command specifies the time in seconds that the polling instance waits for a response
to a ping packet. You may find a higher time-out useful in networks where ping packets
have a low priority.
The no variant of this command resets the set time out to the default of one second.
Syntax
timeout <1-30>
no timeout
Default
The default is 1 second.
Mode
Ping-Polling Configuration
Examples
To specify the timeout as 5 seconds for ping-poll instance 43, use the commands:
To reset the timeout to its default of 1 second for ping-poll instance 43, use the
commands:
Related Commands
critical-interval
fail-count
normal-interval
ping-poll
sample-size
show ping-poll
up-count
Parameter
Description
<1-30>
Length of time, in seconds, that the polling instance waits for a
response from the polled device.
awplus#
configure terminal
awplus(config)#
ping-poll 43
awplus(config-ping-poll)#
timeout 5
awplus#
configure terminal
awplus(config)#
ping-poll 43
awplus(config-ping-poll)#
no timeout