log email (filter)
This command creates a filter to select messages to be sent to an email address. Selection
can be based on the priority/ severity of the message, the program that generated the
message, the logging facility used, a sub-string within the message or a combination of
some or all of these.
The no variant of this command configures the device to no longer send log messages to
a specified email address. All configuration relating to this log target will be removed.
Syntax
log email
[facility
no log email
[facility
Parameter
Description
The email address to send logging messages to
level
Filter messages by severity level.
<level>
The minimum severity of messages to send. The level can be
specified as one of the following numbers or level names, where 0 is
the highest severity and 7 is the lowest severity:
0 emergencies:
System is unusable
1 alerts
Action must be taken immediately
2 critical
Critical conditions
3 errors
Error conditions
4 warnings
Warning conditions
5 notices
Normal, but significant, conditions
6 informational
Informational messages
7 debugging
Debug-level messages
program
Filter messages by program. Include messages from a specified
program in the log.