beautypg.com

Clock timezone – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual

Page 210

background image

System Configuration and Monitoring Commands

Software Reference for x310 Series Switches

8.10

AlliedWare Plus

TM

Operating System - Version 5.4.4C

C613-50046-01 REV A

clock timezone

This command defines the device’s clock timezone. The timezone is set as a offset to the
UTC.

The no variant of this command resets the system time to UTC.

By default, the system time is set to UTC.

Syntax

clock timezone {minus|plus} [<0-13>|<0-12>:<00-59>]

no clock timezone

Mode

Global Configuration

Usage

Configure the timezone before setting the local time. Otherwise, when you change the
timezone, the device applies the new offset to the local time.

Examples

To set the timezone to New Zealand Standard Time with an offset from UTC of +12 hours,
use the command:

To set the timezone to Indian Standard Time with an offset from UTC of +5:30 hours, use
the command:

To set the timezone back to UTC with no offsets, use the command:

Related Commands

clock set
clock summer-time date
clock summer-time recurring

Parameter

Description

name>

A description of the timezone, up to 6 characters long.

minus or

plus

The direction of offset from UTC. The minus option indicates that
the timezone is behind UTC. The plus option indicates that the
timezone is ahead of UTC.

<0-13>

The offset in hours or from UTC.

<0-12>:<00-59>

The offset in hours or from UTC.

awplus(config)#

clock timezone NZST plus 12

awplus(config)#

clock timezone IST plus 5:30

awplus(config)#

no clock timezone