clock timezone
This command defines the device’s clock timezone. The timezone is set as a offset to the
UTC.
The no variant of this command resets the system time to UTC.
By default, the system time is set to UTC.
Syntax
clock timezone
no clock timezone
Mode
Global Configuration
Usage
Configure the timezone before setting the local time. Otherwise, when you change the
timezone, the device applies the new offset to the local time.
Examples
To set the timezone to New Zealand Standard Time with an offset from UTC of +12 hours,
use the command:
To set the timezone to Indian Standard Time with an offset from UTC of +5:30 hours, use
the command:
To set the timezone back to UTC with no offsets, use the command:
Related Commands
clock set
clock summer-time date
clock summer-time recurring
Parameter
Description
A description of the timezone, up to 6 characters long.
minus or
plus
The direction of offset from UTC. The minus option indicates that
the timezone is behind UTC. The plus option indicates that the
timezone is ahead of UTC.
<0-13>
The offset in hours or from UTC.
<0-12>:<00-59>
The offset in hours or from UTC.
awplus(config)#
clock timezone NZST plus 12
awplus(config)#
clock timezone IST plus 5:30
awplus(config)#