Logging Commands

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

10.19

Mode

Global Configuration

Examples

To create a filter to send all messages generated by EPSR that have a severity of notices
or higher to the email address [email protected] use the following commands:

To create a filter to send all messages containing the text “Bridging
initialization”

, to the email address [email protected] use the following

commands:

To create a filter to send messages with a severity level of informational and above to
the email address [email protected] use the following commands:

To stop the device emailing log messages emailed to the email address
[email protected]

use the following commands:

To remove a filter that sends all messages generated by EPSR that have a severity of
notices

or higher to the email address [email protected] use the following

commands:

To remove a filter that sends messages with a severity level of informational and
above to the email address [email protected] use the following
commands:

Related Commands

default log email
log email
show log config

awplus#

configure terminal

awplus(config)#

log email [email protected] level notices
program epsr

awplus#

configure terminal

awplus(config)#

log email [email protected] msgtext
"Bridging initialization"

awplus#

configure terminal

awplus(config)#

log email [email protected] level
informational

awplus#

configure terminal

awplus(config)#

no log email [email protected]

awplus#

configure terminal

awplus(config)#

no log email [email protected] level
notices program epsr

awplus#

configure terminal

awplus(config)#

no log email [email protected] level
informational