Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 291
Logging Commands
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
10.19
Mode
Global Configuration
Examples
To create a filter to send all messages generated by EPSR that have a severity of notices
or higher to the email address [email protected] use the following commands:
To create a filter to send all messages containing the text “Bridging
initialization”
, to the email address [email protected] use the following
commands:
To create a filter to send messages with a severity level of informational and above to
the email address [email protected] use the following commands:
To stop the device emailing log messages emailed to the email address
[email protected]
use the following commands:
To remove a filter that sends all messages generated by EPSR that have a severity of
notices
or higher to the email address [email protected] use the following
commands:
To remove a filter that sends messages with a severity level of informational and
above to the email address [email protected] use the following
commands:
Related Commands
default log email
log email
show log config
awplus#
configure terminal
awplus(config)#
log email [email protected] level notices
program epsr
awplus#
configure terminal
awplus(config)#
log email [email protected] msgtext
"Bridging initialization"
awplus#
configure terminal
awplus(config)#
log email [email protected] level
informational
awplus#
configure terminal
awplus(config)#
no log email [email protected]
awplus#
configure terminal
awplus(config)#
no log email [email protected] level
notices program epsr
awplus#
configure terminal
awplus(config)#
no log email [email protected] level
informational