sFlow Introduction and Configuration

Software Reference for x310 Series Switches

80.12

AlliedWare Plus

TM

Operating System - Version 5.4.4C

C613-50046-01 REV A

Step 4:

Check the Configuration

View the sFlow Configuration

awplus#

do show running-config sflow

Validate that sFlow is enabled
Note that the prefix “do” enables you to run
an Exec Mode command from an Interface
Mode prompt.

Figure 80-3: Output from the show-running config sFlow command

awplus#sh run sflow
!
sflow agent ip 192.0.2.33
sflow collector ip 192.0.2.65
sflow collector max-datagram-size 1200
sflow enable
!
interface port1.0.13-port1.0.22
sflow sampling-rate 2750