RMON Introduction and Configuration

Software Reference for x310 Series Switches

73.4

AlliedWare Plus

TM

Operating System - Version 5.4.4C

C613-50046-01 REV A

Step 4:

Enable RMON traps.

To ensure that the SNMP trap is sent, you need to enabled RMON traps, and you need
to define a trap host in SNMP. Use the below commands to configure this
functionality:

Note that the resulting log message will be of the form listed below:

awplus#

configure terminal

awplus(config)#

snmp-server

awplus(config)#

snmp-server enable trap rmon

awplus(config)#

snmp-server community public

awplus(config)#

snmp-server host 192.168.2.254 version 2c
public

RMON [1024]: Alarm Index 5 alarm Rising Threshold 5000 alarm
Value 5117 alarm Rising event Index 10 event description
RMON_SNMP