beautypg.com

Show port-vlan-forwarding-priority – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual

Page 434

background image

VLAN Commands

Software Reference for x310 Series Switches

17.6

AlliedWare Plus

TM

Operating System - Version 5.4.4C

C613-50046-01 REV A

show port-vlan-forwarding-priority

Use this command to display the highest priority protocol that controls port-vlan
forwarding or blocking traffic. This command displays whether EPSR or Loop Protection is
set as the highest priority for determining whether a port forwards a VLAN, as set by the

port-vlan-forwarding-priority

command.

For more information about EPSR, see the section

“EPSR Introduction and

Configuration” on page 57.1

.

Syntax

show port-vlan-forwarding-priority

Mode

Privileged Exec

Example

To display the highest priority protocol, use the command:

Output

Figure 17-1: Example output from the show port-vlan-forwarding-priority command

Related Commands

port-vlan-forwarding-priority

awplus#

show port-vlan-forwarding-priority

Port-vlan Forwarding Priority: EPSR