beautypg.com

Spanning-tree portfast bpdu-filter – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual

Page 549

background image

Spanning Tree Commands

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

19.59

spanning-tree portfast bpdu-filter

This command sets the bpdu-filter feature and applies a filter to any BPDUs (Bridge
Protocol Data Units) received. Enabling this feature ensures that configured ports will not
transmit any BPDUs and will ignore (filter out) any BPDUs received. BPDU Filter is not
enabled on a port by default.

Using the no variant of this command to turn off the bpdu-filter, but retain the port’s
status as an enabled port. If the port then receives a BPDU it will change its role from an
edge-port to a non edge-port.

Syntax

(Global

Configuration)

spanning-tree portfast bpdu-filter

no spanning-tree portfast bpdu-filter

Syntax

(Interface

Configuration)

spanning-tree portfast bpdu-filter {default|disable|enable}

no spanning-tree portfast bpdu-filter

Default

BPDU Filter is not enabled on any ports by default.

Mode

Global Configuration and Interface Configuration

Usage

This command filters the BPDUs and passes only data to continue to act as an edge port.
Using this command in Global Configuration mode applies the portfast bpdu-filter feature
to all ports on the switch. Using it in Interface mode applies the feature to a specific port,
or range of ports.The command will operate in both RSTP and MSTP networks.

Use the

show spanning-tree

command to display status of the bpdu-filter parameter for

the switch ports.

Parameter

Description

bpdu-filter

A port that has bpdu-filter enabled will not transmit any BPDUs and
will ignore any BPDUs received. This port type has one of the
following parameters (in Interface Configuration mode):

default

Takes the setting that has been configured for the whole
switch, i.e. the setting made from the Global
configuration mode.

disable

Turns off BPDU filter.

enable

Turns on BPDU filter.