Show power-inline interface – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 618
Power over Ethernet Commands
Software Reference for x310 Series Switches
23.20
AlliedWare Plus
TM
Operating System - Version 5.4.4C
C613-50046-01 REV A
show power-inline interface
This command displays a summary of Power over Ethernet (PoE) information for specified
ports. If no ports are specified then PoE information is displayed for all ports on the Power
Sourcing Equipment (PSE).
For information on output options, see
“Controlling “show” Command Output” on
Syntax
show power-inline interface [<port-list>]
Mode
User Exec and Privileged Exec
Usage
To display PoE information for all PoE ports on the PSE, do not specify any ports.
Example
To display the PoE port specific information for all PoE ports on the switch, use the
following command:
To display the PoE port specific information for the port range 1.0.1 to 1.0.4, use the
following command:
Output
Figure 23-4: Example output from the show power-inline interface command
Parameter
Description
<port-list>
Enter the PoE port(s) to display PoE specific information in the show
output.
awplus#
show power-inline interface
awplus#
show power-inline interface port1.0.1-port1.0.4
awplus#show power-inline interface port1.0.1-port1.0.4
Interface Admin Pri Oper Power Device Class Max(mW)
port1.0.1 Disabled Low Disabled 0 n/a n/a n/a
port1.0.2 Enabled High Powered 3840 Desk Phone 1 5000 [U]
port1.0.3 Enabled Crit Powered 6720 AccessPoint 2 7000 [C]
port1.0.4 Disabled Low Disabled 0 n/a n/a n/a