Start-up Sequence

Software Reference for x310 Series Switches

3.14

AlliedWare Plus

TM

Operating System - Version 5.4.4C

C613-50046-01 REV A

There are three possible status results displayed for each module loaded - OK, INFO,
ERROR:

OK means that the module has loaded correctly.

INFO means that an error occurred, but the device is usable.

ERROR means that an error occurred and device operation may be affected.

Additional specific information accompanies an INFO or ERROR status result. For example,
if a corrupt release file was set as the startup release, the following error message would
be seen:

Whether an error message results in a case of the device being unusable will depend on
the specific error and message, so will need to be dealt with on a case by case basis. If a
software release has been corrupted, as shown on start-up, a new release may need to be
loaded.

Bootloader 1.0.9 loaded
Press for the Boot Menu
Reading filesystem...
Error: Release filename is invalid (should be x310-5.4.4C.rel)
Error: There is no backup release file set
Error: Boot failed. Please recover the system using the Boot Menu
Restarting...Bootloader 1.0.9 loaded
Press for the Boot Menu