Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 2017

Triggers Configuration
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
76.11
Capture Show Output and Save to a USB
Storage Device
The following configuration allows you to automatically capture output from the
command when a USB storage device is inserted into the switch. It uses a
script called by the USB storage device trigger to capture the show tech-support output
and places this output in a file on the USB storage device.
■
Trigger 9 activates the script shtech-sup.scp when a USB storage device is inserted in
the switch
1.
Create the shtech-sup.scp script
Create a configuration script with the commands that are executed when the trigger
conditions are met. You can either create the configuration script using the CLI with
the
command or create a script on a PC then load it onto your device using the
command. The configuration script for this example is:
2.
Configure trigger 9
To create trigger 9, use the commands:
Set the trigger to activate on the insertion of a USB storage device:
Add the script shtech-sup.scp to the trigger:
3.
Verify the configuration
To check the configuration of the triggers, use the command:
!
enable
show tech-support outfile usb:support.txt.gz
exit
end
!
awplus#
configure terminal
awplus(config)#
trigger 9
awplus(config-trigger)#
type usb in
awplus(config-trigger)#
script 1 shtech-sup.scp
awplus#
show trigger 9