Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 1839
![background image](/manuals/427254/1839/background.png)
SNMP MIBs
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
69.27
atEnvMonv2FaultLed1Flash
{ atEnvMonv2FaultLedEntry 2 }
Indicates whether a fault LED is currently showing a system
failure by flashing once. Values can be:
1. heatsinkFanFailure (1) - indicates that one or more
heatsink fans have failed, or are operating below the
recommended speed
2. noFault (2)
atEnvMonv2FaultLed2Flashes
{ atEnvMonv2FaultLedEntry 3 }
Indicates whether a fault LED is currently showing a system
failure by flashing twice. Values can be:
1. chassisFanFailure (1) - indicates that one or both of the
chassis fans are not installed, or the fans are operating
below the recommended speed
2. noFault (2)
atEnvMonv2FaultLed3Flashes
{ atEnvMonv2FaultLedEntry 4 }
Indicates whether a fault LED is currently showing a system
failure by flashing three times. Values can be:
1. sensorFailure (1) - indicates that the ability to monitor
temperature or fans has failed
2. noFault (2)
atEnvMonv2FaultLed4Flashes
{ atEnvMonv2FaultLedEntry 5 }
Indicates whether a fault LED is currently showing a system
failure by flashing four times. Values can be:
1. xemInitialisationFailure (1) - indicates that a XEM failed
to initialise or is incompatible
2. noFault (2)
atEnvMonv2FaultLed5Flashes
{ atEnvMonv2FaultLedEntry 6 }
Indicates whether a fault LED is currently showing a system
failure by flashing five times. Values can be:
1. alarmMonitorAlarm (1) - indicates that the Alarm
Monitor has detected one or more fault conditions.
2. noFault (2)
atEnvMonv2FaultLed6Flashes
{ atEnvMonv2FaultLedEntry 7 }
Indicates whether a fault LED is currently showing a system
failure by flashing six times. Values can be:
1. temperatureFailure (1) - indicates that the device’s
temperature has exceeded the recommended
threshold
2. noFault (2)
atEnvMonv2ContactInputTable
{ atEnvMonv2 7 }
(1.3.6.1.4.1.207.8.4.4.3.12.7)
Table of information about contact inputs available in the
device that are monitored by environment monitoring
hardware, indexed by:
■
atEnvMonv2ContactInputStackMemberId
■
atEnvMonv2ContactInputBoardIndex
■
atEnvMonv2ContactInputIndex
atEnvMonv2ContactInputEntry
{ atEnvMonv2ContactInputTable 1 }
The description and current state of a contact input.
atEnvMonv2ContactInputStackMemberId
{ atEnvMonv2ContactInputEntry 1 }
Index of the stack member hosting this input contact.
atEnvMonv2ContactInputBoardIndex
{ atEnvMonv2ContactInputEntry 2 }
Index of the board hosting this input contact in the board
table.
atEnvMonv2ContactInputIndex
{ atEnvMonv2ContactInputEntry 3 }
The numeric identifier of this contact input on its host
board.
Table 69-8: Objects defined in AT-ENVMONV2-MIB(cont.)
Object / Object Identifier
Description