SNMP MIBs

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

69.27

atEnvMonv2FaultLed1Flash
{ atEnvMonv2FaultLedEntry 2 }

Indicates whether a fault LED is currently showing a system
failure by flashing once. Values can be:

1. heatsinkFanFailure (1) - indicates that one or more

heatsink fans have failed, or are operating below the
recommended speed

2. noFault (2)

atEnvMonv2FaultLed2Flashes
{ atEnvMonv2FaultLedEntry 3 }

Indicates whether a fault LED is currently showing a system
failure by flashing twice. Values can be:

1. chassisFanFailure (1) - indicates that one or both of the

chassis fans are not installed, or the fans are operating
below the recommended speed

2. noFault (2)

atEnvMonv2FaultLed3Flashes
{ atEnvMonv2FaultLedEntry 4 }

Indicates whether a fault LED is currently showing a system
failure by flashing three times. Values can be:

1. sensorFailure (1) - indicates that the ability to monitor

temperature or fans has failed

2. noFault (2)

atEnvMonv2FaultLed4Flashes
{ atEnvMonv2FaultLedEntry 5 }

Indicates whether a fault LED is currently showing a system
failure by flashing four times. Values can be:

1. xemInitialisationFailure (1) - indicates that a XEM failed

to initialise or is incompatible

2. noFault (2)

atEnvMonv2FaultLed5Flashes
{ atEnvMonv2FaultLedEntry 6 }

Indicates whether a fault LED is currently showing a system
failure by flashing five times. Values can be:

1. alarmMonitorAlarm (1) - indicates that the Alarm

Monitor has detected one or more fault conditions.

2. noFault (2)

atEnvMonv2FaultLed6Flashes
{ atEnvMonv2FaultLedEntry 7 }

Indicates whether a fault LED is currently showing a system
failure by flashing six times. Values can be:

1. temperatureFailure (1) - indicates that the device’s

temperature has exceeded the recommended
threshold

2. noFault (2)

atEnvMonv2ContactInputTable
{ atEnvMonv2 7 }

(1.3.6.1.4.1.207.8.4.4.3.12.7)

Table of information about contact inputs available in the
device that are monitored by environment monitoring
hardware, indexed by:

atEnvMonv2ContactInputStackMemberId

atEnvMonv2ContactInputBoardIndex

atEnvMonv2ContactInputIndex

atEnvMonv2ContactInputEntry
{ atEnvMonv2ContactInputTable 1 }

The description and current state of a contact input.

atEnvMonv2ContactInputStackMemberId

{ atEnvMonv2ContactInputEntry 1 }

Index of the stack member hosting this input contact.

atEnvMonv2ContactInputBoardIndex

{ atEnvMonv2ContactInputEntry 2 }

Index of the board hosting this input contact in the board
table.

atEnvMonv2ContactInputIndex

{ atEnvMonv2ContactInputEntry 3 }

The numeric identifier of this contact input on its host
board.

Table 69-8: Objects defined in AT-ENVMONV2-MIB(cont.)

Object / Object Identifier

Description