System Configuration and Monitoring Commands

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

8.57

Table 8-8: Parameters in the output from the show system pluggables detail
command:

Related Commands

show system environment
show system pluggable
show system pluggable diagnostics

Parameter

Description

Stack member

The stack member number..

Port

Specifies the port the pluggable transceiver is installed in.

Vendor Name:

Specifies the vendor’s name for the installed pluggable
transceiver.

Device Name:

Specifies the device name for the installed pluggable
transceiver.

Device Type:

Specifies the device type for the installed pluggable
transceiver..

Serial Number:

Specifies the serial number for the installed pluggable
transceiver.

Manufacturing
Datecode:

Specifies the manufacturing datecode for the installed
pluggable transceiver. Checking the manufacturing
datecode with the vendor may be useful when determining
Laser Diode aging issues. See the

Trouble-shoot fiber and

pluggable issues

section in the

System Configuration and

Monitoring Commands

chapter.

SFP Laser
Wavelength:

Specifies the laser wavelength of the installed pluggable
transceiver.

Single Mode
Fiber:

Specifies the link length supported by the pluggable
transceiver using single mode fiber.

OM1 (62.5um)
Fiber:

Specifies the link length (in μm - micron) supported by the
pluggable transceiver using 62.5 micron multi-mode fiber.

OM2 (50um) Fiber:

Specifies the link length (in μm - micron) supported by the
pluggable transceiver using 50 micron multi-mode fiber.

Diagnostic
Calibration:

Specifies whether the pluggable transceiver supports DDM
or DOM Internal or External Calibration:
Internal is displayed if the pluggable transceiver supports
DDM or DOM Internal Calibration.
External is displayed if the pluggable transceiver supports
DDM or DOM External Calibration.
- is displayed if SFP or SFP+ DDM Internal Calibration or
External Calibration is not supported.

Power Monitoring:

Displays the received power measurement type, which can
be either OMA (Optical Module Amplitude) or Avg (Average
Power) measured in μW.