SNMP Introduction

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

67.7

Syntax

The syntax of an object describes the abstract data structure corresponding to that object
type. For example, INTEGER or OCTET STRING.

Access

The access mode of an object describes the level of access for the object.

Access modes for MIB objects:

Status

The status of an object describes the implementation requirements for the object.

Status values for MIB objects:

Description

The definition of an object may include an optional textual description of the meaning
and use of the object. This description is often essential for successful understanding of
the object.

Access

Description

Read-only

The object’s value can be read but not set.

Read-write

The object’s value can be read and set.

Write-only

The object’s value can be set but not read.

Not-accessible

The object’s value cannot be read or set.

Status

Description

Mandatory

Managed devices must implement the object.

Optional

Managed devices may implement the object.

Obsolete

Managed devices need no longer implement the object.

Deprecated

Managed devices should implement the object. However, the
object may be deleted from the next version of the MIB. A new
object with equal or superior functionality is defined.