beautypg.com

Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual

Page 1840

background image

SNMP MIBs

Software Reference for x310 Series Switches

69.28

AlliedWare Plus

TM

Operating System - Version 5.4.4C

C613-50046-01 REV A

atEnvMonv2ContactInputDescription

{ atEnvMonv2ContactInputEntry 4 }

The description of this contact input.

atEnvMonv2ContactInputState

{ atEnvMonv2ContactInputEntry 5 }

Current state of the input contact - closed (1) or open (2).

atEnvMonv2ContactIOutputTable
{ atEnvMonv2 8}

Table of information about contact outputs available in the
device that are managed by environment monitoring
hardware, indexed by:

1. atEnvMonv2ContactOutputStackMemberId

2. atEnvMonv2ContactOutputBoardIndex
3. atEnvMonv2ContactOutputIndex

atEnvMonv2ContactOutputEntry
{ atEnvMonv2ContactOutputTable 1 }

atEnvMonv2ContactOutputStackMemberId

{ atEnvMonv2ContactInputEntry 1 }

Index of the stack member hosting this output contact.

atEnvMonv2ContactOutputBoardIndex

{ atEnvMonv2ContactInputEntry 2 }

Index of the board hosting this contact output in the board
table.

atEnvMonv2ContactOutputIndex

{ atEnvMonv2ContactInputEntry 3 }

The numeric identifier of this contact output on its host
board.

atEnvMonv2ContactOutputDescription

{ atEnvMonv2ContactInputEntry 4 }

The description of this contact output.

atEnvMonv2ContactOutputState

{ atEnvMonv2ContactInputEntry 5 }

Current state of the output contact - closed (1) or open (2).

atEnvMonv2ExternalPSUTable
{ atEnvMonv2 9}

Table of information about external power supply status
monitored by environment monitoring hardware, indexed
by:

1. atEnvMonv2ExternalPSUStatusStackMemberId

2. atEnvMonv2ExternalPSUStatusBoardIndex
3. atEnvMonv2ExternalPSUStatusIndex

atEnvMonv2ExernalPSUEntry
{ atEnvMonv2ExternalPSUStatusTable 1 }

atEnvMonv2ExternalPSUStackMemberId

{ atEnvMonv2ExternalPSUEntry 1 }

Index of the stack member hosting this external power
supply.

atEnvMonv2ExternalPSUBoardIndex

{ atEnvMonv2ExternalPSUEntry 2 }

Index of the board hosting this external power supply in
the board table.

atEnvMonv2ExternalPSUIndex

{ atEnvMonv2ExternalPSUEntry 3 }

The numeric identifier of this external power supply on its
host board.

atEnvMonv2ExternalPSUDescription

{ atEnvMonv2ExternalPSUEntry 4 }

The description of this external power supply.

atEnvMonv2ExternalPSUState

{ atEnvMonv2ExternalPSUEntry 5 }

Current state of the output contact - good (1) or failed (2).

Table 69-8: Objects defined in AT-ENVMONV2-MIB(cont.)

Object / Object Identifier

Description