normal-interval
This command specifies the time period between pings when the device is reachable.
The no variant of this command resets the time period to the default of 30 seconds.
Syntax
normal-interval <1-65536>
no normal-interval
Default
The default is 30 seconds.
Mode
Ping-Polling Configuration
Examples
To specify a time period of 60 seconds between pings when the device is reachable for
ping-poll instance 45, use the commands:
To reset the interval to the default of 30 seconds for ping-poll instance 45, use the
commands:
Related Commands
critical-interval
fail-count
ping-poll
sample-size
show ping-poll
timeout (ping polling)
up-count
Parameter
Description
<1-65536>
Time in seconds between pings when the target is reachable.
awplus#
configure terminal
awplus(config)#
ping-poll 45
awplus(config-ping-poll)#
normal-interval 60
awplus#
configure terminal
awplus(config)#
ping-poll 45
awplus(config-ping-poll)#
no normal-interval