beautypg.com

Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual

Page 212

background image

System Configuration and Monitoring Commands

Software Reference for x310 Series Switches

8.12

AlliedWare Plus

TM

Operating System - Version 5.4.4C

C613-50046-01 REV A

To set the period to 500 and action to stopreboot, use the commands:

To return the period and action to the defaults and keep the continuous reboot
prevention feature enabled, use the commands:

To disable continuous reboot prevention, use the commands:

Related Commands

show continuous-reboot-prevention
show reboot history
show tech-support

awplus#

configure terminal

awplus(config)#

continuous-reboot-prevention period 500
action stopreboot

awplus#

configure terminal

awplus(config)#

no continuous-reboot-prevention period action

awplus#

configure terminal

awplus(config)#

no continuous-reboot-prevention enable