beautypg.com

Polarity – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual

Page 388

background image

Switching Commands

Software Reference for x310 Series Switches

15.26

AlliedWare Plus

TM

Operating System - Version 5.4.4C

C613-50046-01 REV A

polarity

This command sets the MDI/MDIX polarity on a copper-based switch port.

Syntax

polarity {auto|mdi|mdix}

Default

By default, switch ports set the polarity automatically (auto).

Mode

Interface Configuration

Usage

We recommend the default auto setting for MDI/MDIX polarity. Polarity applies to copper
10BASE-T, 100BASE-T, and 1000BASE-T switch ports; It does not apply to fibre ports. For
more information, see

“MDI/MDIX Connection Modes” on page 14.5

.

Example

To set the polarity for port1.0.6 to fixed MDI mode, use the following commands:

Parameter

Description

mdi

Sets the polarity to MDI (medium dependent interface).

mdix

Sets the polarity to MDI-X (medium dependent interface crossover).

auto

The switch port sets the polarity automatically. This is the default option.

awplus#

configure terminal

awplus(config)#

interface port1.0.6

awplus(config-if)#

polarity mdi