Add the script LEDoff.scp to the trigger:
Specify a helpful description, such as Shutdown power to LEDs. Use the command:
Change to Global Configuration mode:
4.
Configure trigger 7
To create trigger 7, use the command:
Set the trigger to activate at 8.30am:
Set the trigger to activate on Monday, Tuesday, Wednesday, Thursday and Friday:
Add the script LEDon.scp to the trigger:
Specify a helpful description, such as Turn on power to LEDs. Use the command:
5.
Verify the configuration
To check the configuration of the triggers, use the commands:
awplus(config-trigger)#
script 1 LEDoff.scp
awplus(config-trigger)#
description Shutdown power to LEDs
awplus(config-trigger)#
exit
awplus(config)#
trigger 9
awplus(config-trigger)#
type time 08:30
awplus(config-trigger)#
day mon tue wed thur fri
awplus(config-trigger)#
script 1 LEDon.scp
awplus(config-trigger)#
description Turn on power to LEDs
awplus#
show trigger 6
awplus#
show trigger 7