Triggers Configuration

Software Reference for x310 Series Switches

76.8

AlliedWare Plus

TM

Operating System - Version 5.4.4C

C613-50046-01 REV A

Add the script LEDoff.scp to the trigger:

Specify a helpful description, such as Shutdown power to LEDs. Use the command:

Change to Global Configuration mode:

4.

Configure trigger 7

To create trigger 7, use the command:

Set the trigger to activate at 8.30am:

Set the trigger to activate on Monday, Tuesday, Wednesday, Thursday and Friday:

Add the script LEDon.scp to the trigger:

Specify a helpful description, such as Turn on power to LEDs. Use the command:

5.

Verify the configuration

To check the configuration of the triggers, use the commands:

awplus(config-trigger)#

script 1 LEDoff.scp

awplus(config-trigger)#

description Shutdown power to LEDs

awplus(config-trigger)#

exit

awplus(config)#

trigger 9

awplus(config-trigger)#

type time 08:30

awplus(config-trigger)#

day mon tue wed thur fri

awplus(config-trigger)#

script 1 LEDon.scp

awplus(config-trigger)#

description Turn on power to LEDs

awplus#

show trigger 6

awplus#

show trigger 7