beautypg.com

Stack renumber cascade – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual

Page 2163

background image

Stacking Commands

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

83.23

stack renumber cascade

This command is used to renumber the members of a stack so that their IDs are ordered
sequentially, relative to the member's physical position within the stack.

Syntax

stack <stack-ID> renumber cascade [<stack-ID>]

Default

If no stack-ID is specified, the member will take the default ID of 1.

Mode

Global Configuration

Usage

This command is used to renumber the members of a stack so that their stack-IDs are
ordered sequentially, based on physical order of the XEM-STK connections. This would
normally be done either when the stack is initially configured or following a major
reconfiguration.

This command is equivalent to pressing and holding the select button on the XEM-STK to
renumber the stack members. The renumber will start on the specified stack member. If
that stack-ID is not used by any of the existing stack member, the command will be
rejected.

The starting stack member will be renumbered with the new stack-ID specified, or the
default of member ID of 1. The stack-ID of the next physically will be the starting members
ID +1, for example member ID 2. This renumbering will continue in cascading order
around the stack members.

The changes will take place immediately and reboot all stack members. For this reason a
confirmation prompt follows this command entry, asking whether you are sure you want
to renumber and reboot the entire stack.

Example

Related Commands

show stack
stack renumber

Caution

Changing the stack numbering will upset the existing stack member
configurations such as port settings etc. This command is intended for use
when the stack is either initially commissioned, or has undergone a major
reconfiguration. In this situation you run the stack renumber command
(which will automatically reboot the switch), then configure the stack
members to meet the new requirements.

Parameter

Description

The ID of the stack member to start renumbering from, (from 1 to 4).

renumber

Change the existing stack-ID.

cascade

Renumber the existing stack-ID in cascade order.

The new ID for the first member renumbered, from 1 to 4.

awplus(config)#

stack 1 renumber cascade

Any existing interface configuration may no longer be valid

Are you sure you want to renumber and reboot the entire stack?

(y/n):

y