Service power-inline – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 611
Power over Ethernet Commands
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
23.13
service power-inline
This command enables Power over Ethernet (PoE) globally on the Power Sourcing
Equipment (PSE) for all PoE ports.
Syntax
service power-inline
no service power-inline
Default
PoE functionality is enabled by default on the PSE.
Mode
Global Configuration
Usage
In a stack, issuing this command enables PoE globally for all PoE ports.
In a stack configuration, only stack members containing PoE hardware will have PoE
enabled by default in software.
Examples
To disable PoE on the PSE, use the following commands:
To re-enable PoE on the PSE, if PoE has been disabled, use the following commands:
Validation
Commands
show power-inline
show running-config power-inline
awplus#
configure terminal
awplus(config)#
no service power-inline
awplus#
configure terminal
awplus(config)#
service power-inline