SNMP MIBs

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

69.91

SNMPv2-PDU

RFC 3416, Version 2 of the Protocol Operations for the Simple
Network Management Protocol (SNMP)
.

SNMPv2-TM

RFC 3417, Transport Mappings for the Simple Network
Management Protocol (SNMP)
.

SNMPv2-MIB

RFC 3418, Management Information Base (MIB) for the Simple
Network Management Protocol (SNMP)
.

POE-MIB

RFC 3621, Power Ethernet MIB.

In each of the following objects, if one entry is set then all
other entries for the same object in the table are set to the
same value.

pethMainPseUsageThreshold

pethNotificationControlEnable

The following objects indicate PSE threshold usage
notification:

pethMainPowerUsageOnNotification

pethMainPowerUsageOffNotification

The following read-write object is implemented as
read-only:

pethPsePortPowerPairs

EtherLike-MIB

RFC 3635, Definitions of Managed Objects for the Ethernet-like
Interface Types
.

The following objects are deprecated:

dot3StatsEtherChipSet

all objects in the dot3Tests group

all objects in the dot3Errors group

The following read-write object is implemented as
read-only:

dot3PauseAdminMode

MAU-MIB

RFC 3636, Definitions of Managed Objects for IEEE 802.3
Medium Attachment Units (MAUs)
.

The following objects are not supported:

all objects in the dot3RpMauBasicGroup group

ifMauTypeListBits

ifMauHCFalseCarriers

all object identifiers in the dot3MauType group

ifMauAutoNegCapabilityBits

ifMauAutoNegCapAdvertisedBits

ifMauAutoNegCapReceivedBits

ifMauAutoNegRemoteFaultAdvertised

ifMauAutoNegRemoteFaultReceived

all objects in the mauMod group

The following objects are deprecated:

ifMauTypeList

all objects in the dot3BroadMauBasicGroup group

ifMauAutoNegCapability

ifMauAutoNegCapAdvertised

ifMauAutoNegCapReceived

The following read-write object is implemented as
read-only:

ifMauStatus

INET-ADDRESS-MIB

RFC 4001, Textual Conventions for Internet Network Addresses.

Public MIBs Supported by AlliedWare Plus

TM

(cont.)

MIB Name

Reference / Implementation