Type stack link, Type time, Type stack link {up|down – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 2048: Type time < hh:mm, Type stack link type time

Trigger Commands
Software Reference for x310 Series Switches
77.28
AlliedWare Plus
TM
Operating System - Version 5.4.4C
C613-50046-01 REV A
type stack link
This command (configured to the stack) initiates the action of a pre-configured trigger to
occur when a stacking link is either activated or deactivated.
Syntax
type stack link {up|down}
Mode
Trigger Configuration
Example
To configure trigger 86 to activate when the stack link down event occurs, use the
commands:
Related Commands
show trigger
trigger
type stack master-fail
type time
This command configures a trigger that activates at a specified time of day.
Syntax
type time <hh:mm>
Mode
Trigger Configuration
Usage
A combined limit of 10 triggers of the type time and type periodic can be configured. If
you attempt to add more than 10 triggers the following error message is displayed:
Example
To configure trigger 86 to activate at 15:53, use the following commands:
Related Commands
Parameter
Description
up
Stack link up event
down
Stack link down event
awplus#
configure terminal
awplus(config)#
trigger 86
awplus(config-trigger)#
type stack link down
Parameter
Description
<hh:mm>
The time to activate the trigger.
% Cannot configure more than 10 triggers with the type time or
periodic
awplus#
configure terminal
awplus(config)#
trigger 86
awplus(config-trigger)#
type time 15:53