log monitor (filter)

This command creates a filter to select messages to be sent to the terminal when the
terminal monitor command is given. Selection can be based on the priority/severity of the
message, the program that generated the message, the logging facility used, a sub-string
within the message or a combination of some or all of these.

Syntax

log monitor [level ] [program ]

[facility ] [msgtext ]

no log monitor [level ] [program ]

[facility ] [msgtext ]

Parameter

Description

level

Filter messages to the permanent log by severity level.

<level>

The minimum severity of message to send to the log. The level can be
specified as one of the following numbers or level names, where 0 is
the highest severity and 7 is the lowest severity:

0|emergencies: System

is

unusable

1|alerts

Action must be taken immediately

2|critical

Critical conditions

3|errors

Error conditions

4|warnings

Warning conditions

5|notices

Normal, but significant, conditions

6|informational

Informational messages

7|debugging

Debug-level messages

program

Filter messages to the permanent log by program. Include messages
from a specified program in the log.

<program-
name
>

The name of a program to log messages from, either one of the
following predefined program names (not case-sensitive), or another
program name (case -sensitive) that you find in the log output.

rsvp

Resource Reservation Protocol (RSVP)

dot1x

IEEE 802.1X Port-Based Access Control

lacp

Link Aggregation Control Protocol (LACP)

stp

Spanning Tree Protocol (STP)

rstp

Rapid Spanning Tree Protocol (RSTP)

mstp

Multiple Spanning Tree Protocol (MSTP)

imi

Integrated Management Interface (IMI)

<program-
name
>
(cont.)

imish

Integrated Management Interface Shell (IMISH)

epsr

Ethernet Protection Switched Rings (EPSR)

irdp

ICMP Router Discovery Protocol (IRDP)

rmon

Remote Monitoring

loopprot

Loop Protection

poe

Power-inline (Power over Ethernet)

dhcpsn

DHCP snooping (DHCPSN)

facility

Filter messages to the permanent log by syslog facility.