Logging Commands

Software Reference for x310 Series Switches

C613-50046-01 REV A

AlliedWare Plus

TM

Operating System - Version 5.4.4C

10.29

Default

By default there is a filter to select all messages. This filter may be removed and replaced
by filters that are more selective.

Mode

Global Configuration

Examples

To create a filter to send all messages generated by MSTP that have a severity of info or
higher to terminal instances where the terminal monitor command has been given use
the following commands:

To remove a filter that sends all messages generated by EPSR that have a severity of
notices

or higher to the terminal use the following commands:

To remove a default filter that includes sending everything to the terminal use the
following commands:

Validation

Commands

show log config

Related Commands

terminal monitor

<facility>

Specify one of the following syslog facilities to include messages from
in the log:

kern

Kernel messages

user

Random user-level messages

mail

Mail system

daemon

System daemons

auth

Security/authorization messages

syslog

Messages generated internally by syslogd

lpr

Line printer subsystem

news

Network news subsystem

uucp

UUCP subsystem

cron

Clock daemon

authpriv

Security/authorization messages (private)

ftp FTP

daemon

msgtext

Select messages containing a certain text string

<text-
string
>

A text string to match. This is case sensitive, and must be the last text
on the command line.

Parameter

Description

awplus#

configure terminal

awplus(config)#

log monitor level info program mstp

awplus#

configure terminal

awplus(config)#

no log monitor level notices program epsr

awplus#

configure terminal

awplus(config)#

no log monitor level debugging