Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 301
Logging Commands
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
10.29
Default
By default there is a filter to select all messages. This filter may be removed and replaced
by filters that are more selective.
Mode
Global Configuration
Examples
To create a filter to send all messages generated by MSTP that have a severity of info or
higher to terminal instances where the terminal monitor command has been given use
the following commands:
To remove a filter that sends all messages generated by EPSR that have a severity of
notices
or higher to the terminal use the following commands:
To remove a default filter that includes sending everything to the terminal use the
following commands:
Validation
Commands
Related Commands
<facility>
Specify one of the following syslog facilities to include messages from
in the log:
kern
Kernel messages
user
Random user-level messages
Mail system
daemon
System daemons
auth
Security/authorization messages
syslog
Messages generated internally by syslogd
lpr
Line printer subsystem
news
Network news subsystem
uucp
UUCP subsystem
cron
Clock daemon
authpriv
Security/authorization messages (private)
ftp FTP
daemon
msgtext
Select messages containing a certain text string
<text-
string>
A text string to match. This is case sensitive, and must be the last text
on the command line.
Parameter
Description
awplus#
configure terminal
awplus(config)#
log monitor level info program mstp
awplus#
configure terminal
awplus(config)#
no log monitor level notices program epsr
awplus#
configure terminal
awplus(config)#
no log monitor level debugging