23.15
show power-inline
This command displays the Power over Ethernet (PoE) status for all ports on the Power
Sourcing Equipment (PSE).
For information on output options, see
“Controlling “show” Command Output” on
Syntax
show power-inline
Mode
User Exec and Privileged Exec
Example
To display the PoE status for all ports on the PSE, use the following command:
Output
Figure 23-2: Example output from the
command
awplus#
show power-inline
awplus#show power-inline
PoE Status:
Stack Member 2
Nominal Power: 370W
Power Allocated: 246W
Actual Power Consumption: 151W
Operational Status: On
Power Usage Threshold: 80% (296W)
PoE Interface:
Interface Admin Pri Oper Power Device Class Max(mW)
port2.0.1 Enabled Low Powered 3840 n/a 1 4000 [C]
port2.0.2 Enabled High Powered 6720 n/a 2 7000 [C]
port2.0.3 Enabled Low Powered 14784 n/a 3 15400 [C]
port2.0.4 Enabled Crit Powered 14784 n/a 3 15400 [C]
port2.0.5 Enabled Crit Powered 3840 n/a 1 4000 [C]
port2.0.6 Enabled High Powered 6720 n/a 2 7000 [C]
port2.0.7 Enabled Low Powered 14784 n/a 3 15400 [C]