Auth-web-server ping-poll interval – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 1177
![background image](/manuals/427254/1177/background.png)
Authentication Commands
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
43.51
auth-web-server ping-poll interval
This command is used to change the ping poll interval. The interval specifies the time
period between pings when the supplicant (client device) is reachable.
Use the no variant of this command to reset to the default period for ping polling (30
seconds).
Syntax
auth-web-server ping-poll interval <1-65535>
no auth-web-server ping-poll interval
Default
The interval for ping polling is 30 seconds by default.
Mode
Global Configuration
Examples
To set the interval of ping polling to 60 seconds, use the following commands:
To set the interval of ping polling to the default (30 seconds), use the following
commands:
Validation
Commands
show auth-web-server
show running-config
Parameter
Description
<1-65535>
Seconds.
awplus#
configure terminal
awplus(config)#
auth-web-server ping-poll interval 60
awplus#
configure terminal
awplus(config)#
no auth-web-server ping-poll interval