loop-protection

Use this command to enable the loop-protection loop-detection feature, and configure
the detection mechanism parameters.

Use the no variant of this command to disable the loop-protection loop-detection feature.

Syntax

loop-protection loop-detect [ldf-interval ]

[ldf-rx-window ]

no loop-protection [loop-detect]

Default

The loop-protection loop-detection feature is disabled by default.
The default interval is 10 seconds, and the default window size is 3 frames.

Mode

Global Configuration

Usage

See the

Loop Protection

section in

Chapter 14, Switching Introduction

for relevant

conceptual, configuration, and overview information prior to applying this command.

Example

To enable the loop-detect mechanism on the switch, and generate loop-detect frames
once every 5 seconds, use the following commands:

Related Commands

loop-protection action
loop-protection timeout
show loop-protection
thrash-limiting

Parameter

Description

loop-detect

Enables loop detection when used with loop-protection
keywords. Disables loop detection when used with no loop-
protection keywords.

ldf-interval

The time (in seconds) between successive loop-detect frames
being sent.

Specify a period between 1 and 600 seconds.
The default is 10 seconds.

ldf-rx-window

The number of transmitted loop detection frames whose
details are held for comparing with frames arriving at the same
port.

Specify a value for the window size between 1 and 5 frames.
The default is 3 frames.

awplus#

configure terminal

awplus(config)#

loop-protection loop-detect ldf-interval 5