Critical-interval, Command, Critical-interval <1-65536 – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 2063
![background image](/manuals/427254/2063/background.png)
Ping-Polling Commands
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
79.5
critical-interval
This command specifies the time period in seconds between pings when the polling
instance has not received a reply to at least one ping, and when the device is unreachable.
This command enables the device to quickly observe changes in state, and should be set
to a much lower value than the
command.
The no variant of this command sets the critical interval to the default of one second.
Syntax
critical-interval <1-65536>
no critical-interval
Default
The default is 1 second.
Mode
Ping-Polling Configuration
Examples
To set the critical interval to 2 seconds for the ping-polling instance 99, use the
commands:
To reset the critical interval to the default of one second for the ping-polling instance 99,
use the commands:
Related Commands
fail-count
normal-interval
sample-size
show ping-poll
timeout (ping polling)
up-count
Parameter
Description
<1-65536>
Time in seconds between pings, when the device has failed to
a ping, or the device is unreachable.
awplus#
configure terminal
awplus(config)#
ping-poll 99
awplus(config-ping-poll)#
critical-interval 2
awplus#
configure terminal
awplus(config)#
ping-poll 99
awplus(config-ping-poll)#
no critical-interval